Permissible flank contact pressures

Guide values for the permissible flank contact pressures can be found in the following table. For shaft calculation, take account of the reduction in strength as a result of the feather key connections

Material

Permissible contact pressure pper under load type

N/mm2

Static Pulsating
Steel, unhardened 100…200 70…150
Steel, hardened 150…250 100…170
Cast steel 100…150 80…100
Cast iron, malleable cast iron 80…100 60…80
Copper alloy (bronze, brass) 40…50 30…40
AlCuMg, aged 100…160 70…100
AlMg, AlMn, AlMgSi, aged 80…150 60…90
G AlSi, G AlSiMg 60…70 40…50

In general, the higher values apply in the case of higher values for yield stress, fracture strength and hardness of the materials, while the lower values apply accordingly in the case of lower strength values.

  • The values apply in the range Rm=400…1 200 N/mm2 (in accordance with DIN 741)